Carrier Air Conditioner Error Codes

Troubleshooting and Error Codes for Carrier Air Conditioners

The list below features all the malfunction error codes for Carrier air conditioners and their potential causes.  You may determine the state and problem of the air conditioner or air conditioning system by looking up the error code.

Carrier air conditioner error codes Mackay

Carrier Air Conditioner Indoor Unit Error Codes

Code Possible Cause
E0 Indoor unit EEPROM parameter error
E1 Indoor / outdoor units communication error
E3 Indoor fan speed has been out of control
E4 Indoor room temperature sensor T1 open circuit or short circuit
E5 Evaporator coil temperature sensor T2 open circuit or short circuit
EC Refrigerant Leakage Detection
F1 Outdoor ambient temperature sensor T4 open circuit or short circuit
F2 Condenser coil temperature sensor T3 open circuit or short circuit
F3 Compressor discharge temperature sensor T5 open circuit or short circuit
F4 Outdoor unit EEPROM parameter error
F5 Outdoor fan speed has been out of control
P0 IPM malfunction or IGBT over-strong current protection
P1 Over voltage or over low voltage protection
P2 High temperature protection of compressor top diagnosis and solution
P4 Inverter compressor drive error
P5 Mode conflict
P6 Compressor voltage protection

Carrier Air Conditioner Outdoor Unit Error Codes

Code Possible Cause
E0 Outdoor EEPROM malfunction
E2 Indoor/outdoor units communication error
E3 Communication malfunction between IPM board and outdoor main board
E4 Open or short circuit of outdoor unit temperature sensor
E5 Voltage protection
E8 Outdoor fan speed malfunction
F1 No A Indoor unit coil outlet temperature sensor or connector of sensor is defective
F2 No B Indoor unit coil outlet temperature sensor or connector of sensor is defective
F3 No C Indoor unit coil outlet temperature sensor or connector of sensor is defective
F4 No D Indoor unit coil outlet temperature sensor or connector of sensor is defective
F5 No E Indoor unit coil outlet temperature sensor or connector of sensor is defective
P1 High pressure protection
P2 Low pressure protection
P3 Current protection of compressor
P4 Temperature protection of compressor
P5 High temperature protection of condenser
P6 IPM module protection

Other Carrier Air Conditioner Error Codes

Code Possible Cause
DN Communication error between main board and EXV.
EC Refrigerant leakage detection.
EE Memory card error.
EN Frequency limitation for module circuit protection.
EU Frequency limitation for module temperature protection.
FH Frequency limitation for freeze protection.
H1 Defrost or heating oil return cycle.
H3 Compressor overheat protection.
H5 IPM Protection.
H7 Compressor speed reduction.
HC PFC protection malfunction.
HE Compressor demagnetizing protection.
L9 Compressor high voltage protection.
LC Compressor start-up failure.
LD Compressor phase loss protection.
LE Compressor stalling.
LF Compressor over-speed protection.
LP Indoor and outdoor units mismatch.
PA Input current protection.
PC Current sensor malfunction.
PD Current sensor miss-wiring protection.
PF Inverter board ambient temperature sensor malfunction.
PH High voltage protection.
PL Low voltage protection.
PP Abnormal input AC voltage.
PU Capacitor charging malfunction.
Carrier indoor air conditioner error codes Mackay
Carrier outdoor air conditioner error codes Mackay

These are the common issues for Carrier Air Conditioners

Problem Possible Causes Solutions
Air Conditioner is Freezing Up Dirty filter/coils; Refrigerant leak Clean the AC unit; Contact a technician
Air Conditioner is Making a Whirring Sound Faulty fan motor Replace fan motor
Air Conditioner is Short Cycling Clogged filter; Faulty capacitor/condenser Clean AC unit; Inspect the components of the AC
Air Conditioner has Electrical Issues Loose wires; Tripped breakers Contact an electrician

The Air Conditioner is Freezing Up

A common AC issue with several air conditioning brands is a frozen air conditioner. A refrigerant leak may also be the cause of a frozen evaporator coil, but filthy air filters and coils are the usual causes of air conditioner freeze-ups.

After letting the ice melt, clean your unit to get rid of extra dust and dirt from the air filter. If clearing the clogged air filter does not resolve the issue, get in touch with an AC contractor to locate and address the refrigerant line leak.

My Air Conditioner is Making a Whizzing Noise

The noise produced by air conditioners is minimal. The unit’s motors may ordinarily produce quiet, low-pitched humming sounds, but a loud, whizzing sound denotes a problem. A whirring, engine sound is frequently a sign of a malfunctioning fan motor, which must be replaced by a qualified professional to resolve the problem and stop additional harm to your machine.

My Air Conditioner is Short Cycling

You may tell something is wrong with your air conditioning system when it keeps turning on and off for many minutes at a time. Short cycling is the problem that keeps your air conditioner from adequately chilling the space.

Quick repairs for clogged filters and blocked return air ducts are frequently the cause of short cycling. Take a moment to clean your unit and get rid of any obstructions or clogs. If this doesn’t resolve the issue, get your HVAC system inspected by an air conditioning contractor. It’s possible that there are issues with the condensing unit, capacitor, or other hard-to-find parts.

My Air Conditioner has Electrical Problems

Is the circuit breaker being tripped by your air conditioner? Simply turn the switch back on and unplug as many of the gadgets from around the house, and the issue ought to go away. But any problems relating to the power supply, including loose sockets, damaged wiring, or power outages, need to be handled by an expert, so get in touch with your electrician right now.

Air Conditioner Brand Error Codes

Click on the brand below for their air conditioner error codes and faults.